Troubleshooting

This page lists the situations you are most likely to hit and how to resolve them. Status words (SW=...) are the two-byte codes returned by the card.

No readers found

“No smart card readers found.”

  • Confirm the reader is connected: shamir-cli reader list.

  • On Linux, ensure pcscd is running: sudo systemctl status pcscd.

  • You may need permissions — run under sudo or add your user to the pcscd group.

  • Remember: only contact readers work. NFC / contactless is rejected.

Command not allowed (SW=6985)

The card’s state machine refused the command in its current state.

  • You issued a step out of order (e.g. exporting a share before the seed was generated).

  • The simplest fix is to reset and start the workflow again:

    shamir-cli orchestrator reset
    

Note

The guided workflows (The Ceremony, Recovery) drive the state machine for you. If you see 6985 while using them, the card was likely left in a partial state — reset it and re-run.

Wrong data / crypto error (SW=6A80)

A cryptographic check failed. Common causes:

  • The cards do not belong to the same set (a storage card from another set, or mixed with another orchestrator).

  • The wrong RSA key was supplied for wrapping.

Re-run the workflow from a clean reset, using cards from the same set.

Wrong PIN

``SW=63CX`` — “Wrong PIN, X tries remaining”.

  • X is the number of attempts left before lockout.

  • After three wrong attempts, the card locks.

  • The factory default PIN is 0000.

Warning

A locked storage card cannot be read with its PIN. With an Admin card (PIN level C) you can reset it; otherwise the three-attempt budget is precious — keep PINs in your custody records. See Storage card PIN — security levels.

Resetting a stuck card

If a card is left in a non-initial state (for example after an interrupted ceremony), simply reset it:

# Orchestrator
shamir-cli orchestrator reset

# Storage (PIN required)
shamir-cli storage reset --pin 0000

If a storage card’s PIN is lost or locked (after three wrong attempts):

  • With an Admin card (PIN level C) — reset the card’s PIN with the Admin card and set a new one. The card and its share are recovered. This is the recommended setup (see Storage card PIN — security levels).

  • Without an Admin card (level A/B) — the card cannot be unlocked; it, and the share it holds, are lost. As long as you still have k working cards, recovery is unaffected; if you drop below k, the secret can no longer be reconstructed from the cards.

Note

The orchestrator is different: it holds no secret at rest. If an orchestrator card is lost, damaged, or locked, it is not a security concern — request a replacement orchestrator card (matched to your card set) from Cryptnox at contact@cryptnox.com. Your storage cards and their shares are unaffected.

Cards still “Loaded” before a new ceremony

If a storage card reports state 0x02 (Loaded), it still holds a share from a previous ceremony. Reset it first:

shamir-cli storage reset --pin 0000

Recovery produced the wrong secret

The recovery completed but the Recovery checksum does not match the checksum recorded at the ceremony.

  • Cause: the cards were inserted in the wrong order, or cards from a different ceremony were mixed in. The system relies on inserting cards in share-index order (Card order (share numbers)).

  • Fix: do not import the result. Re-run, inserting the correctly labelled cards (#1 first, #2 second, …).

Important

Always verify the Recovery checksum against your ceremony record before importing a recovered seed into an HSM.

Reconstruction is slow

On-card reconstruction performs modular inversions, which are expensive on a smart card. A large threshold on a large curve (for example k = 7 on P-521) can take on the order of a second. This is expected.

See also